<ErrorMessage>
ALE2: Drum is not safe: Head Stage is at away position
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
With the head stage away tab active, both drum and carriage movements are considered
unsafe and hence blocked.  To remedy the situation, move the head stage away from the drum
until the away tab is inactive.  This can be done with the following stage commands:
stage moveto
stage init
stage home
Use the "stage" command to query the home/away status if required.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
None.
</text></DescriptionText>
</OperatorAction>
<Cause>
A drum action has been requested while the head stage is in a position activating it's away tab.
Or the cable to the head stage home/away board may be disconnected.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/stage.xml</LinkAddress><LinkTitle>Command: stage</LinkTitle></Link>
<Link><LinkAddress>../commands/stage_moveto.xml</LinkAddress><LinkTitle>Command: stage moveto</LinkTitle></Link>
<Link><LinkAddress>../commands/stage_init.xml</LinkAddress><LinkTitle>Command: stage init</LinkTitle></Link>
<Link><LinkAddress>../commands/stage_home.xml</LinkAddress><LinkTitle>Command: stage home</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:56 2008 PST
</Updated>
<Links>
</Links>
</Error>